Industrial Baltur Burner

Technical Descriptions:

    • Gas burner compliant with European standard EN676. Electronic operation at two progressive stages.
    • Continuous modulation operation by installing P.I.D. controller in the control panel (to be ordered separately with modulation probe).
    • Modulation ratio 1:5.
    • Gas burner with low NOx and CO emissions in accordance with European standard EN676: class 3.
    • Regulating combustion air and blast-pipe.
    • Combustion air intake with throttle damper. Air flow adjustment with electric servomotor.
    • Combustion air intake designed to achieve optimum linearity of the air gate opening.
    • Fully closing air damper on shutdown to avoid loss of heat through the chimney.
    • Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.
    • Sliding boiler coupling flange to adapt the blast-pipe to the various types of boilers.
    • Easy maintenance thanks to the two-sides hinge which allows the removal of the combustion head without having to remove the burner from the boiler.
    • Device made of sound-absorbing material to reduce fan noise.
    • CE version gas train is complete with butterfly valve, operation and safety valve with electromagnetic drive, valve tightness control, minimum pressure switch, pressure regulator and gas filter.
    • Fail proof connectors for burner/gas train connection
    • Gas train exit: high/low.
    • Flame detection by ionization electrode with connector for micro amp meter.
    • Control panel equipped either with display showing the working process and with the keyboard for the burner adjustment.
    • Electric control board in light aluminum alloy with IP55 protection rating
    • 7-pole socket for burner electric and thermostatic supply.
    • 4-pole socket for second stage control or for the connection of the PID electronic regulator.
    • Electrical system with protection rating IP44.

Comments

Popular posts from this blog

BULK TEMPERATURE AND ITS SAFE WORKING IN THERMIC FLUID HEATER

Thermic Fluid Heater is most popular in almost every industry, and it is being used for various heating applications due to unique advantage over other heating systems like steam heating, electrical heating, direct firing, air heating etc. In many of the applications, it is very cost effective and energy saving as it has an exceptional advantage over other industrial heating methods. Thus, it is important to recognize various aspects of thermic fluid heating and significance of thermal oil temperature when thermic fluid circulate through tubes of heater. When fluid flowing inside the coils or tubes of the heater, it creates multiple layers of flow of the fluid along the tube periphery and this layer is almost stationery in a form of a film. This formation of film offers very high resistance to flow of heat from the heat source through heated metal surf...

Industrial Combustion Burner: Basics of "Industrial Burner"

Industrial Engineering involves creating products that maximize function, value, and appearance for professional manufacturers and consumers. Gas burner, Oil burner, or Coal burner is relate to a mechanical device that burns a gas or liquid fuel in a controlled manner. An oil burner (engine) is a steam engine that uses oil as its fuel. Gas burner , a piece of metal fitted to the end of a gas pipe, with one or more small holes so arranged as to spread out the flame. An oil burner is a part that join to an oil furnace, water heater, or boiler. A Low NOx burner is a type of burner that is typically used in utility boilers to produce steam and electricity. The burner is simply a hollow metal disk with holes punctured through its perimeter. And a gas pilot light or electric pilot sits to one side of the burner and sends a small flame or spark to ignite the oxygen-gas mixture as it flows through the holes in the burner. Industrial Gas burner is a device to generate a flame to heat up produ...

HIGH PRESSURE GAS TRAIN Components | Industrial Products

A Typical Fuel Train or High Pressure Gas Train has several components, each with a specific purpose which is briefly explained below: Manual shut-off valve (MSOV) – the purpose of this valve is to shut off the fuel  supply so that maintenance or replacement of the fuel train may be done. Gas pressure regulator (PRV) – its purpose is to maintain the fuel at a constant  pressure as recommended by the burner manufacturer. Gas Filter – the function is to prevent foreign particle and extraneous impurities  entering Gas Pressure Regulator. Low pressure gas switch – senses a low pressure in the range where the burner  cannot properly operate. This switch must be equipped with safety lock-out requiring manual reset. This tells the operator to check the gas pressure, since the burner will not try to restart until the switch is reset. Safety shut-off valve (SSOV) – the first of two valves in series that automatically  opens and shuts off the fuel supply to the burner...