Industrial Burner-Technical Descriptions:

  • Burner with alternate methane gas/diesel fuel supply, EC approved according to European Directives EN676 and EN267. Gas side modulating operation, diesel side two-stage
  • Modulation ratio 1:4.
  • Gas side burner with low NOx and CO emissions in accordance with European standard EN676: class 3.
  • Burner with Low NOx and CO emissions on light oil according to European standard EN267:
  • Regulating combustion air and blast-pipe.
  • Combustion air intake with throttle damper. Air flow adjustment with electric servomotor.
  • Combustion air intake designed to achieve optimum linearity of the air gate opening.
  • Fully closing air damper on shutdown to avoid loss of heat through the chimney.
  • Maintenance facilitated by the possibility of removing the combustion head without having to remove the burner from the boiler.
  • Sliding boiler coupling flange to adapt the blast-pipe to the various types of boilers.
  • Easy maintenance thanks to the two-sides hinge which allows the removal of the combustion head without having to remove the burner from the boiler.
  • CE version gas train is complete with butterfly valve, operation and safety valve with electromagnetic drive, valve tightness control, minimum pressure switch, pressure regulator and gas filter.
  • Fail proof connectors for burner/gas train connection
  • Gas train exit: high.
  • Pump connected to fan motor through electromagnetic clutch.
  • Fuel supply circuit made of gear pump with pressure adjustment, shut-off valves and safety valve
  • Manual fuel switching.
  • Flame detection by means of infrared IRD photocell.
  • Control panel equipped either with display showing the working process and with the keyboard for the burner adjustment.
  • Electric control board in light aluminum alloy with IP55 protection rating
  • 7-pole socket for burner electric and thermostatic supply.
  • 4-pole socket for second stage control or for the connection of the PID electronic regulator.
  • Electrical system with protection rating IP54.

Comments

Popular posts from this blog

HIGH PRESSURE GAS TRAIN Components | Industrial Products

A Typical Fuel Train or High Pressure Gas Train has several components, each with a specific purpose which is briefly explained below: Manual shut-off valve (MSOV) – the purpose of this valve is to shut off the fuel  supply so that maintenance or replacement of the fuel train may be done. Gas pressure regulator (PRV) – its purpose is to maintain the fuel at a constant  pressure as recommended by the burner manufacturer. Gas Filter – the function is to prevent foreign particle and extraneous impurities  entering Gas Pressure Regulator. Low pressure gas switch – senses a low pressure in the range where the burner  cannot properly operate. This switch must be equipped with safety lock-out requiring manual reset. This tells the operator to check the gas pressure, since the burner will not try to restart until the switch is reset. Safety shut-off valve (SSOV) – the first of two valves in series that automatically  opens and shuts off the fuel supply to the burner. On burners above 1200

SIDE STREAM FILTRATION SYSTEM FOR SYNTHETIC THERMIC FLUID

  SIDE STREAM FILTRATION SYSTEM FOR SYNTHETIC THERMIC FLUID Hot Thermic Fluid Filter in side stream operation:   HEATRAN ENGINEERS  provides filtration systems that are extremely efficient for cleaning and maintaining the efficiency of heat transfer fluids or thermal hot oils. HEATRAN systems are for in-line side stream / in-system filtration. Our in house design of filter housings and SS Filter elements (Grade 304 stainless steel possesses “good oxidation resistance in intermittent service to 870 °C and in continuous service to 925 °C”) suitable for the system fluid is proprietary and offers great flexibility and durability with re-usable filter elements to minimize the recurring expense on other type of elements and to enhance optimum cleaning of the Thermic fluid at elevated temperatures, since they can withstand system temperatures of up to 399°C. These elements have excellent dirt-holding capacity, are economical and reusable. HEATRAN housing design allow the self-cleaning capabil

USE OF THERMIC FLUID HEATERS, ENSURING RELIABILITY AND LONGER LIFE FOR THERMIC FLUID

Thermic Fluid Heater is most popular in almost every industries and it is being used for various heating applications due to unique advantage over other heating systems like steam heating, electrical heating, direct firing, air heating etc., because of the following exceptional advantages:- Very low working pressure and safe from explosion hazards. Heat transfer medium or working fluid remains in liquid phase throughout and higher overall heat transfer. Greater efficiency of heat utilization , superior fuel-saving possibility, and better return on investment for the industry. No botheration continuous water treatment for feed water in case of steam boiler. No problem of scale deposition on heating surface. New generation thermic fluids with excellent properties are available in the market Better heat transfer coefficient, higher thermal stability, and long-life cycle Exemption from Indian Boiler Regulations Act and related formalities Thus, many unique advantages when selecting the the