Thermic fluid heaters and its working temperature is always a perplexing term and it is also mostly misunderstood expressions. Generally, all thermic fluid manufacturers recommend certain economic operating temperature or optimum fluid bulk temperature based on its useful life of the product. Hence, the manufacturer of Thermic Fluid Heaters recommends a continuous operating temperature of 300° degrees Centigrade for such a heater in their expectations or estimation of temperature profiles.

But it is important to understand various aspects of temperature when thermic fluid flows through tubes of heater. When fluid flowing in the coils or tubes of the heater, a very thin layer of the fluid all along the metal periphery vehemently adheres to the solid metal very strongly. This layer never moves and form a film or layer which is a stationary oil film. This film creates very high resistance to heat flow from outer heated metal surface to circulating thermic fluid. This resistance depends on the velocity and thickness of the film formed. Thus, the more heat is passed through this film and gain heat in the bulk oil and the resultant temperature of the film is always higher than bulk temperature of the oil and bulk temperature depends on the velocity of the thermic fluid flow in the heater coil.

Therefore, lower film thickness permits higher bulk temperature through higher thermic fluid flow velocity of fluid in tube. Difference between bulk temperature and film temperature with higher flow velocity can be estimated as low as 20°-25° degrees Centigrade. On other side, with low velocity of the fluid in tube can make film temperature difference to the tune of 70° -75° degrees Centigrade. So, film temperature is very crucial for the life of tube and thermic fluid. Therefore, thermic fluid flow velocity through helical tube coil is very critical and it is one of the determinants of film temperature. When heater outlet bulk temperature measured is 280° degrees Centigrade and its film temperature with a good design for optimum velocity can limit film temperature above 20° to 25° degrees Centigrade to bulk temperature and film temperature will be in the tune of 300° to 305° degrees Centigrade. In case of low fluid flow velocity due to inadequate design, the film temperature can go to 70° to 75° degrees Centigrade above operating bulk temperature which results in fluid acquiring film temperature of 350° to 355° degrees Centigrade and it is near to the dangerous level and boiling point of even synthetic thermic fluid and mineral oils is always disadvantageously have lower boiling point.

The film temperature goes above boiling point, vapor is formed along the metal periphery and this is much less viscous and thinner than liquid oil film and adhere far more rapidly and it has high resistance which is hundred times higher than liquid film resistance. This vapor film in the periphery of the tubes interfere and will not allow to transfer the heat to thermic fluid and tube surface get exposed to the hot combustion gases and heat at the outside of the tubes. This kind of overheating on the metal surface is also called “hot spot” heating and it will cause cracks on tubes whereby explosive low flash point hydrocarbon gases are formed. The vapor film above the desired temperature is capable enough to crack the fluid to lighter hydrocarbon gases or low boilers thereby reducing flash point of fluid drastically.

So, it is vital to understand the significance of bulk temperature and film temperature for the thermic fluid heater manufacturers and their proper and appropriate usage.


BY: MADHUSOODANAN.S

(Author is presently working as a Principal Consultant – Nirmal Encon Services, Director Technical - HeatranEngineers Pvt Ltd, and Group Executive Chairman & Managing Director - Nirmal Energy Limited & its associated companies, Ahmedabad and having more than three decades of experience in the similar fields.)

Comments

Popular posts from this blog

Industrial Combustion Burner: Basics of "Industrial Burner"

Industrial Engineering involves creating products that maximize function, value, and appearance for professional manufacturers and consumers. Gas burner, Oil burner, or Coal burner is relate to a mechanical device that burns a gas or liquid fuel in a controlled manner. An oil burner (engine) is a steam engine that uses oil as its fuel. Gas burner , a piece of metal fitted to the end of a gas pipe, with one or more small holes so arranged as to spread out the flame. An oil burner is a part that join to an oil furnace, water heater, or boiler. A Low NOx burner is a type of burner that is typically used in utility boilers to produce steam and electricity. The burner is simply a hollow metal disk with holes punctured through its perimeter. And a gas pilot light or electric pilot sits to one side of the burner and sends a small flame or spark to ignite the oxygen-gas mixture as it flows through the holes in the burner. Industrial Gas burner is a device to generate a flame to heat up produ

HIGH PRESSURE GAS TRAIN Components | Industrial Products

A Typical Fuel Train or High Pressure Gas Train has several components, each with a specific purpose which is briefly explained below: Manual shut-off valve (MSOV) – the purpose of this valve is to shut off the fuel  supply so that maintenance or replacement of the fuel train may be done. Gas pressure regulator (PRV) – its purpose is to maintain the fuel at a constant  pressure as recommended by the burner manufacturer. Gas Filter – the function is to prevent foreign particle and extraneous impurities  entering Gas Pressure Regulator. Low pressure gas switch – senses a low pressure in the range where the burner  cannot properly operate. This switch must be equipped with safety lock-out requiring manual reset. This tells the operator to check the gas pressure, since the burner will not try to restart until the switch is reset. Safety shut-off valve (SSOV) – the first of two valves in series that automatically  opens and shuts off the fuel supply to the burner. On burners above 1200

SIDE STREAM FILTRATION SYSTEM FOR SYNTHETIC THERMIC FLUID

  SIDE STREAM FILTRATION SYSTEM FOR SYNTHETIC THERMIC FLUID Hot Thermic Fluid Filter in side stream operation:   HEATRAN ENGINEERS  provides filtration systems that are extremely efficient for cleaning and maintaining the efficiency of heat transfer fluids or thermal hot oils. HEATRAN systems are for in-line side stream / in-system filtration. Our in house design of filter housings and SS Filter elements (Grade 304 stainless steel possesses “good oxidation resistance in intermittent service to 870 °C and in continuous service to 925 °C”) suitable for the system fluid is proprietary and offers great flexibility and durability with re-usable filter elements to minimize the recurring expense on other type of elements and to enhance optimum cleaning of the Thermic fluid at elevated temperatures, since they can withstand system temperatures of up to 399°C. These elements have excellent dirt-holding capacity, are economical and reusable. HEATRAN housing design allow the self-cleaning capabil